Spedizione gratuita con Packeta per un prezzo superiore a 79.99 €
BRT 7.99 Punto BRT 7.99 DHL 7.99 HR Parcel 7.49 GLS 3.99

Fan-Beam Multiplexed Compton Scatter Tomography for Single-Sided Noninvasive Inspection

Lingua IngleseInglese
Libro In brossura
Libro Fan-Beam Multiplexed Compton Scatter Tomography for Single-Sided Noninvasive Inspection Brian L Evans
Codice Libristo: 08243307
Casa editrice Biblioscholar, novembre 2012
Energies, the scattered gamma ray spectra are significantly influenced by the momentum distribution... Descrizione completa
? points 168 b
71.07
Magazzino esterno Inviamo tra 15-20 giorni

30 giorni per il reso


Potrebbe interessarti anche


African Whiteboy Ian Watson / In brossura
common.buy 22.90
Pieces of a Plan Christopher Daryl Hannon / In brossura
common.buy 24.50
Ceremonies of Innocence John D. Bernard / Rigido
common.buy 70.85
Account of the British Settlement at Aden, in Arabia. Frederick Mercer Hunter / In brossura
common.buy 33.81

Energies, the scattered gamma ray spectra are significantly influenced by the momentum distribution of the electrons in the target, a phenomenon known as Doppler broadening. This broadening is energy-variant and the shape is a function of scattering material. A deterministic system model is developed that implements advanced features such as Doppler broadening, extended source and detector sizes, and the spatially-variant and energy-variant aspects of detector response. These features allow direct simulation without convolving an idealized model with an experimentally-measured detector response function. Likewise, it allows the direct use of measured spectra for image reconstruction without deconvolving the detector response function. Two novel approaches to image reconstruction are developed, one based on filtered backprojection and another based on an iterative technique. The filtered backprojection method requires unfolding a scattering angle distribution from each measured energy distribution. Several iterative methods are described to perform this unfolding step. The iterative image reconstruction method is based on a penalized weighted least-squares (PWLS) linear system solution, but implements a two-level iteration to account for nonlinear implicit dependencies in the system. A demonstration MCST system was assembled from components available commercially. This system includes a 6-element array of HPGe detectors, a 109Cd radionuclide that emits 88 keV gammas, and fan beam collimators developed specifically for this system. It is used to produce the first one-sided MCST images from several aluminum phantoms. This validates the system model and iterative image reconstruction algorithm, and demonstrates the feasibility of the one-sided MCST technique. The response of a next-generation MCST system is simulated. The simulations address such issues as the contrast recovered from various samples, system efficiencies, and counting times.

Informazioni sul libro

Titolo completo Fan-Beam Multiplexed Compton Scatter Tomography for Single-Sided Noninvasive Inspection
Autore Brian L Evans
Lingua Inglese
Rilegatura Libro - In brossura
Data di pubblicazione 2012
Numero di pagine 172
EAN 9781288317387
ISBN 9781288317387
Codice Libristo 08243307
Casa editrice Biblioscholar
Peso 318
Dimensioni 189 x 246 x 9
Regala questo libro oggi stesso
È facile
1 Aggiungi il libro al carrello e scegli la consegna come regalo 2 Ti invieremo subito il buono 3 Il libro arriverà all'indirizzo del destinatario

Accesso

Accedi al tuo account. Non hai ancora un account Libristo? Crealo ora!

 
obbligatorio
obbligatorio

Non hai un account? Ottieni i vantaggi di un account Libristo!

Con un account Libristo, avrai tutto sotto controllo.

Crea un account Libristo