Spedizione gratuita con Packeta per un prezzo superiore a 79.99 €
BRT 7.99 Punto BRT 7.99 DHL 7.99 HR Parcel 7.49 GLS 3.99

Accuracy of Working Length using Radiographic method and Root ZX

Lingua IngleseInglese
Libro In brossura
Libro Accuracy of Working Length using Radiographic method and Root ZX Ashwini Santosh
Codice Libristo: 07084966
Casa editrice LAP Lambert Academic Publishing, novembre 2011
The determination of an accurate working length is one of the most critical steps of endodontic ther... Descrizione completa
? points 132 b
55.97
Presso l'editore su ordinazione Inviamo tra 3-5 giorni

30 giorni per il reso


Potrebbe interessarti anche


At the Sign of the Guillotine. Edward Spender / In brossura
common.buy 29.75
Breve Manual del Software Libre Maxima Robert Ipanaqué Chero / In brossura
common.buy 104.68
Le système cardiovasculaire dans tous ses états Laurent Mourot / In brossura
common.buy 69.57
GROUP 24 J. P Gazeau / Rigido
common.buy 495.49
Notfallbehandlung Des Akuten Koronarsyndroms Hans-Richard Arntz / Rigido
common.buy 79.09
Analisis del Riesgo En El Proceso de Ordenamiento Territorial Natalia Patricia Torchia / In brossura
common.buy 65.07
Collision Avoidance Systems for Mine Haul Trucks Patrick Glynn / In brossura
common.buy 103.82
Cultures of Representation Benjamin Fraser / Rigido
common.buy 126.84

The determination of an accurate working length is one of the most critical steps of endodontic therapy. The radiographic method has been the standard means of determining the working length.Number of circumstances make this less than ideal method as it is impossible to consistently detect the major and minor foramina or cemento-dentinal junction (CDJ). Electronic root canal measuring devices were developed to reduce the number of radiographs during the treatment, improve the accuracy of the root canal measurement and to save time during the procedure. Many studies have shown that the current generation of electronic devices are accurate between 82-92% when compared to radiographically determined root canal lengths. A study was done evaluate the accuracy of working length determined using conventional radiograph followed by apex locator in the same tooth and comparing these findings post extraction with the natural apical constriction, after decalcifying the tooth. A stereomicroscope and image analysis unit was used to measure the differences and the results were tabulated and analyzed.

Informazioni sul libro

Titolo completo Accuracy of Working Length using Radiographic method and Root ZX
Lingua Inglese
Rilegatura Libro - In brossura
Data di pubblicazione 2012
Numero di pagine 60
EAN 9783659141027
Codice Libristo 07084966
Peso 106
Dimensioni 150 x 220 x 4
Regala questo libro oggi stesso
È facile
1 Aggiungi il libro al carrello e scegli la consegna come regalo 2 Ti invieremo subito il buono 3 Il libro arriverà all'indirizzo del destinatario

Accesso

Accedi al tuo account. Non hai ancora un account Libristo? Crealo ora!

 
obbligatorio
obbligatorio

Non hai un account? Ottieni i vantaggi di un account Libristo!

Con un account Libristo, avrai tutto sotto controllo.

Crea un account Libristo